TS 275 EVO

Engine Driven Welder Diesel KOHLER KDW702 - Three-phase asynchronous Alternator -  Water cooling

WELDING

  • Welding current: 20A / 20.8V ÷ 270A / 21V (Stick)  |  20A / 10.8V ÷ 270A / 20.8V (Tig)
  • Service: 200A / 28V @ 100%  -  230A / 29.2V @ 60% (Stick)  |  200A / 18V @ 100%  -  230A / 19.2V @ 60%  -  270A / 20.8V @ 35% (Tig)
  • Open circuit voltage (no-load voltage): 66 Vcc (68 Vcc peak)
POWER RATINGS
  • Three-phase power: 8 kVA (6.4kW) / 400 V / 14.4 A
  • Single-phase power: 5 kVA/kW / 230 V / 21.7 A
  • Single-phase power: 2.5 kVA/kW / 110 V / 22.7 A
  • Single-phase power: 5 kVA/kW / 48 V / 104 A
GENERAL SPECIFICATION
  • Tank capacity: 38 l
  • Running time (welder 100%): 11 h
  • Guaranteed acoustic power LwA (pressure LpA): 94 dB(A) (70 dB(A) @ 7 m)
  • Measured acoustic power LwA (pressure LpA): 95 dB(A) (70 dB(A) @ 7 m)
  • Weight: 390 Kg
  • Dimensions max. on base Lxlxh:  1433x710x931 mm

More Information

Engine

Model Fuel Starter Output Stand By Output PRP Cylinders / Displacement Speed Cooled
KOHLER KDW702 Diesel Electric 10.3 kW (14 hp) 9.3 kW (12.6 hp) 2 / 686 cm³ (0.686 lt.) 3000 rpm Water

ENGINE PROTECTION LOVATO

sample powersafe
The Lovato RGK420SA control unit has an ignition key and push buttons for controlling the engine. A wide LCD display allows the visualization of alarms and the monitoring of machine parameters. The main features are:

  • User interface with symbols, codes and texts.
  • Setpoints adjustable via controller buttons or PC
  • Remote Start and Stop
  • Configurable inputs and outputs
  • NFC interface for wireless programming

DOWNLOAD MANUAL



EVO CONTROL

sample powersafe EVO CONTROL is the front panel that using an analog control allows to have features mandatory for users:

  • Current control
  • Arc-force control
  • Half scale to increase the precision of the current control

EVO INSTRUMENTS

sample powersafe EVO INSTRUMENT implements a digital control that adds some features for the user, like:

  • Current control
  • Arc-force control
  • Display to view current and voltage
  • Led to check the VRD status
  • PRE-SETTING