GE 335 FXC

Generator Diesel FPT (IVECO)  C87 TE4 and FPT C87 TE1PV (Stage 3A) - Three-phase synchronous alternator - Water Cooled 

POWER RATINGS THREE-PHASE

  • Stand-By three-phase power: 330 kVA (264 kW) / 400 V / 476.3 A
  • PRP three-phase power: 300 kVA (240 kW) / 400 V / 433 A
  • Frequency: 50 Hz
GENERAL SPECIFICATIONS

  • Fuel tank capacity: 425 lt.
  • Running time (75% to PRP): 9,0 h / 17,5 h (850 lt.)
  • Acoustic pressure: 72 dB(A) @ 7m
  • Dry Weight: 3600 kg / 3800 kg (850 lt.)
  • Dimensions (LxWxH): 3750x2011x1400 mm

More Information

Engine

Model Fuel Starter Output Stand By Output PRP Cylinders / Displacement Speed Cooled
FPT (IVECO) C87 TE4 Diesel Electric 299 kW 275 kW 6/ 8700 cm³ (8.7 lit) 1500 rpm Water
FPT C87 TE1PV (Stage 3A) Diesel Electric 288 kW 256 kW 6/ 8700 cm³ (8.7 lit) 1500 rpm Water

AVR

sample powersafe The Automatic Vcoltage Regulator (AVR) is an electronic device that regulates the voltage level at all times to maintain precise AC output from the generating set. The AVR calculates how much voltage has to be sent to the exciter numerous times a second, therefore stabilising the output voltage to a predetermined set point.

The control characteristics of an AVR system are much more accurate than those of self-regulated alternators.

OPTIONS ON REQUEST